Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38556394

RESUMO

BACKGROUND: Considering the absence of reports validating the precision of the volume score and the relationship between the volume and Agatston scores, this study evaluated the accuracy of the volume score compared to the Agatston score for the quantitative measurement of aortic valve calcification (AVC) on non-electrocardiographic-gated computed tomography (CT). METHODS: We retrospectively analysed the AVC scores of 5385 patients who underwent transthoracic echocardiography between March 1, 2013 and December 26, 2019 â€‹at our institution, using non-contrast non-electrocardiographic-gated CT. The thresholds for significant aortic stenosis (AS) were computed using receiver operating characteristic curves based on the AVC scores. The area under the curve (AUC) of the Agatston and volume scores for significant AS were compared to evaluate the accuracy of the scoring method. RESULTS: All sex-specific AVC thresholds of the volume score for significant AS (moderate and high AS severity, moderate and high AS severity without discordance, discordant severe AS, and concordant severe AS) showed high sensitivity and specificity (AUC, 0.978-0.996; sensitivity, 94.2-98.4%; specificity, 90.1-100%). No significant differences in the AUC were observed between the Agatston and volume scores for significant AS in male and female patients. CONCLUSION: All volume score threshold values showed high sensitivity and specificity for identifying significant AS. The accuracy of the test for AVC thresholds of the volume score for significant AS was comparable to that of the Agatston score. Our findings raise questions about the significance of weighting calcium density in the Agatston score for assessing AS severity.

2.
Cardiovasc Intervent Radiol ; 46(12): 1696-1702, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37902854

RESUMO

PURPOSE: Totally implantable venous access ports (TIVAPs) are increasingly used as safe and convenient central venous access devices. However, several TIVAP-related complications occur, with port/catheter infection being most common. Silver-mixed ports have recently been introduced in anticipation of reducing TIVAP infection. This study aimed to investigate the efficacy of this device in reducing port infection by examining groups with and without silver-mixed devices. MATERIALS AND METHODS: From April 2017 to July 2022, silver-mixed ports (S group) and non-silver-mixed port group (NS group) were reviewed at our institution. The incidence of TIVAP-related infections, patient characteristics, and bacteriological data were evaluated. Univariate and multivariate analyses were used to evaluate risk factors for TIVAP-related infection. RESULTS: A total of 607 patients (S group, n = 203; NS group, n = 404) were enrolled. The rates of TIVAP-related infection were 3.0% (n = 6) and 7.7% (n = 31) in the S and NS groups, respectively. The incidence of total infection per 1000 catheter-days were 0.114 and 0.214 the S and NS groups, respectively. In the entire group, the rates of infection were 6.1% (n = 37) and the incidence of total infection per 1000 catheter-days was 0.187. Univariate and multivariate analyses revealed a significantly lower TIVAP-related infection rate in S group than NS group (p = 0.0216, odds ratio = 2.88 confidence interval: 1.17-7.08). No gram-negative rods were detected in the S group as port infection. CONCLUSION: Silver-mixed port may be feasible in preventing port infection. LEVEL OF EVIDENCE: Level 3, Local non-random sample.


Assuntos
Infecções Relacionadas a Cateter , Cateterismo Venoso Central , Cateteres Venosos Centrais , Humanos , Cateterismo Venoso Central/efeitos adversos , Prata/uso terapêutico , Estudos Retrospectivos , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/prevenção & controle , Cateteres Venosos Centrais/efeitos adversos , Cateteres de Demora/efeitos adversos
3.
J Vasc Interv Radiol ; 34(8): 1416-1423, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37164039

RESUMO

PURPOSE: To evaluate the polymerization properties of a mixture of n-butyl cyanoacrylate (nBCA) and ethiodized oil in the lymphatic system using an animal model. MATERIALS AND METHODS: Nineteen male Japanese White rabbits underwent 28 lymphatic embolization procedures under fluoroscopic guidance using manually injected mixtures of nBCA and ethiodized oil at ratios of 1:2 (nBCA density of 33%), 1:4 (20%), 1:6 (14%), and 1:8 (11%) via the popliteal lymph node. The time required for polymerization and the distance traveled by the mixture were evaluated and compared among the groups using the Kruskal-Wallis test. Histopathologic intergroup comparisons and time-course changes were also evaluated using embolized lymph nodes. RESULTS: Among 23 successful procedures, the mean polymerization times were 14 ± 3, 88 ± 93, 331 ± 292, and 932 seconds ± 540 and the mean distances traveled were 13 ± 10, 31 ± 44, 85 ± 89, and 108 mm ± 35 in the 33% (n = 5), 20% (n = 6), 14% (n = 6), and 11% (n = 6) groups, respectively. The 11% group demonstrated a significantly longer polymerization time than the 33%, 20%, and 14% groups and distance traveled than the 33% group. Pathologically, the embolized lymph nodes showed inflammatory changes and massive necrosis regardless of the nBCA density. CONCLUSIONS: Polymerization times and distances traveled were increased when nBCA was diluted with increasing quantitites of ethiodized oil in this rabbit model of lymphatic embolization. These relationships should be considered when dilution is prescribed for clinical use.


Assuntos
Embolização Terapêutica , Embucrilato , Animais , Coelhos , Masculino , Óleo Etiodado/química , Embucrilato/química , Polimerização , Sistema Linfático , Injeções , Embolização Terapêutica/métodos
4.
Eur Radiol ; 33(2): 1243-1253, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36066729

RESUMO

OBJECTIVES: This study evaluated the association between aortic valve calcification (AVC) and aortic stenosis (AS) by scoring the AVC to determine the threshold scores for significant AS on non-electrocardiographic (ECG)-gated computed tomography (CT). METHODS: We retrospectively analyzed the AVC scores of 5385 patients on non-contrast non-ECG-gated CT, who underwent transthoracic echocardiography (TTE) from March 1, 2013, to December 26, 2019, at our institution. Multivariable logistic regression models were used to identify potential risk factors for significant AS. The thresholds for significant AS were computed using receiver operator characteristic (ROC) curves, based on the AVC scores after propensity score matching. RESULTS: A significant association was found between AS and age (p < 0.001; odds ratio [OR], 1.04; 95% confidence interval [CI], 1.02-1.06), female sex (p < 0.001; OR, 4.5; 95% CI, 2.75-7.36), bicuspid aortic valve (p < 0.001; OR, 23.2; 95% CI, 7.35-72.9), and AVC score (AVC score/100) (p < 0.001; OR, 1.82; 95% CI, 1.71-1.95). All sex-specific AVC thresholds for significant AS (moderate and over AS severity, moderate and over AS severity without discordance, discordant severe AS, and concordant severe AS) showed high sensitivity and specificity (AUC, 0.939-0.968; sensitivity, 84.6-96%; specificity, 84.2-97.1%). CONCLUSIONS: We determined the optimal AVC threshold scores for significant AS, which may aid in diagnosing significant asymptomatic AS on incidental detection of AVC through non-ECG-gated CT for non-cardiac indications. KEY POINTS: • Increased frequency of non-electrocardiographic (ECG)-gated computed tomography (CT) for non-cardiac indications has led to the increased incidental identification of aortic valve calcification (AVC). • It is important to identify patients with significant aortic stenosis (AS) who require additional echocardiographic assessment on incidental detection of AVC via non-ECG-gated CT. • We determined the AVC thresholds with high sensitivity and specificity to identify significant AS on non-ECG-gated CT, which could lead to early diagnosis of asymptomatic significant AS and improved prognosis.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Masculino , Humanos , Feminino , Valva Aórtica/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada Multidetectores/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Índice de Gravidade de Doença
5.
Respir Investig ; 60(4): 595-603, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35581125

RESUMO

BACKGROUND: A single reverse-transcription polymerase chain reaction (RT-PCR) test is not sufficient to exclude COVID-19 in hospital pre-admission screening. However, repeated RT-PCR tests are time-consuming. This study investigates the utility of chest computed tomography (CT) for COVID-19 screening in asymptomatic patients. METHODS: Between April 2020 and March 2021, RT-PCR testing and chest CT were performed to screen COVID-19 in 10 823 asymptomatic patients prior to admission. Chest CT findings were retrospectively evaluated using the reporting system of the Radiological Society of North America. Using RT-PCR results as a reference, we assessed the diagnostic efficacy of chest CT during both the low- and high-prevalence periods of the COVID-19 pandemic. RESULTS: Following a positive RT-PCR test, 20 asymptomatic patients (0.18%) were diagnosed with COVID-19; in the low-prevalence period, 5 of 6556 patients (0.076%) were positive; and in the high-prevalence period, 15 of 4267 patients (0.35%) were positive. Of the 20 asymptomatic COVID-19 positive patients, chest CT results were positive for COVID-19 pneumonia in 8 patients. Chest CT results were false-positive in 185 patients (1.7% false-positive rate, and 60% false-negative rate). Pneumonia that was classified as a "typical appearance" of COVID-19 reported as false-positives in 36 of 39 patients (92.3%). Across the study period, the diagnostic efficacy of "typical appearance" on chest CT were characterized by a sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of 15%, 99.7%, 99.7%, 7.7%, and 99.8%; 20%, 99.6%, 99.6%, 4%, and 99.9%; and 13.3%, 99.7%, 99.7%, 14.3%, and 99.7%, in the entire study, low-, and high-prevalence periods, respectively. CONCLUSIONS: Addition of chest CT to RT-PCR testing provides no benefit to the detection of COVID-19 in asymptomatic patients.


Assuntos
COVID-19 , COVID-19/diagnóstico , COVID-19/epidemiologia , Humanos , Pandemias , Estudos Retrospectivos , Reação em Cadeia da Polimerase Via Transcriptase Reversa , SARS-CoV-2 , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
6.
Jpn J Radiol ; 40(3): 271-278, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34689305

RESUMO

PURPOSE: The purpose of this study was to investigate the usefulness of temporal subtraction CT (TSCT) of temporal bone CT for the detection of postoperative recurrent/residual cholesteatoma of the middle ear. METHODS: Thirty-two consecutive patients with surgically proven postoperative recurrent/residual cholesteatoma and 14 consecutive patients without recurrent/residual lesion matched the selection criteria and were retrospectively evaluated. TSCT imaging was generated with the use of serial postoperative CT. Two experienced radiologists and two residents evaluated the presence of bone erosive change by comparison serial CT studies, and CT and TSCT. The detection rate of bone erosive change, sensitivity and specificity of the recurrence/residual lesions, and reading time for each reader were evaluated. RESULTS: TSCT + CT significantly improved the detection of bone erosive changes compared to CT-only evaluation (17.4-41.3% vs. 37.0-58.7%, p = 0.008-0.046). The mean sensitivity and specificity of TSCT + CT for experienced radiologists were 0.77 and 1.00, and 0.52 and 0.97 without TSCT. The mean sensitivity and specificity of TSCT + CT for residents were 0.64 and 1.00, and 0.41 and 1.00 without TSCT. Sensitivity showed an increase in all readers. The use of TSCT significantly reduced the reading time per case in all readers (p < 0.001). CONCLUSION: TSCT improves the depiction of newly occurring progressive bone erosive changes, and detection sensitivity and reading time in postoperative recurrence/residual cholesteatoma of middle ear.


Assuntos
Colesteatoma da Orelha Média , Colesteatoma da Orelha Média/diagnóstico por imagem , Colesteatoma da Orelha Média/cirurgia , Orelha Média/diagnóstico por imagem , Orelha Média/patologia , Orelha Média/cirurgia , Humanos , Estudos Retrospectivos , Osso Temporal/diagnóstico por imagem , Osso Temporal/cirurgia , Tomografia Computadorizada por Raios X/métodos
7.
World J Surg ; 45(12): 3603-3608, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34415403

RESUMO

BACKGROUND: Plexiform neurofibromas (PNs) are highly vascularized and potentially malignant tumors. Surgical resection of a PN can be complicated by perioperative hemorrhagic events (PHE), including excessive intraoperative blood loss and postoperative hematoma at the surgical site. This study aimed to evaluate the predictive factors of PHE and the usefulness of preoperative embolization for PN. MATERIALS AND METHODS: Consecutive surgical resections of 24 massive PNs in the body trunk with a maximum diameter > 5 cm in 22 patients between January 2015 and December 2020 were reviewed. Patient demographics, laboratory analyses, MRI findings, preoperative transcatheter arterial embolization (TAE), and pathological findings were evaluated between PNs with and without PHE, which consists of intraoperative blood loss over 15% of their estimated total blood volume and/or postoperative hematoma requiring surgical intervention or blood transfusion. RESULTS: PHE was observed in 7 out of 24 PNs (29.2%), with 5 events of excessive intraoperative bleeding and 2 postoperative hematomas. The PHE group (n = 7) showed a significantly higher flow-void effect inside the tumor on preoperative MRI than the non-PHE group (n = 17) (P = 0.0186). Preoperative TAE was not associated with PHE occurrence for the 24 PNs; however, it significantly reduced the PHE risk by 12 PNs with a flow-void sign (P = 0.00126). Other characteristics showed no significant differences between groups. CONCLUSION: The flow-void sign on MRI can be the only predictive factor of PHE in surgical resection for massive PNs in the body trunk. Preoperative TAE can reduce the PHE risk for PNs with a flow-void sign.


Assuntos
Embolização Terapêutica , Neurofibroma Plexiforme , Perda Sanguínea Cirúrgica/prevenção & controle , Transfusão de Sangue , Humanos , Cuidados Pré-Operatórios , Estudos Retrospectivos
8.
Radiol Case Rep ; 15(9): 1623-1628, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32685083

RESUMO

Percutaneous transabdominal lymphangiography and embolization have been reported as useful approaches for intractable chylothorax or chylous ascites. However, they are often difficult to perform after extensive lymph node dissection because disruption of the antegrade lymphatic flow makes leaks identification difficult. When the leakage point cannot be identified or percutaneous transabdominal lymphangiography and embolization fail, a retrograde transvenous approach to the thoracic duct can be used instead. We report 3 cases of refractory chylous ascites after retroperitoneal operation or extensive lymph node dissection that was addressed by retrograde transvenous lymphatic embolization. In one case, a combination of retrograde transvenous lymphatic embolization, transcatheter sclerotherapy, and transcatheter embolization was used. These findings suggest that retrograde transvenous lymphatic embolization appears to be feasible and efficient for postoperative chylous ascites.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...